Spray Foam Insulation:

Under Spray Foam Insulation : As much as 40% of a building’s energy is lost due to air infiltration. Gaps, holes and air leaks—which can all be prevented—can make energy bills unnecessarily high and let valuable resources go to waste.

Spray foam offers a solution: it performs as both insulation and an air sealant, or air barrier, closing those nooks and crannies that let air escape and add dollars to monthly energy bills.

Fireproofing:

DendamixTM is a lightweight spray applied fireproofing product developed by American Sprayed Fibers, Inc. with exceptional fireproofing capabilities. In addition, the product incorporates a high level of sound control and thermal insulation.

DendamixTM is easily spray applied directly to steel, wood, concrete, and other substrates. In addition to providing superior heat protection, this monolithic fireproof coating offers solid in-place durability, and has a very appealing color and texture.

DendamixTM is the product ideally suited to protect:

  • Steel beams & columns

  • Fire breaks

  • Common walls

  • Vertical wall partitions

  • Lightweight partitioning

  • Metal decking

HVAC:

Let us service both Residential and Commercial Customers with maintenance plans to fit your budget. Let us provide your yearly maintenance tune-ups to ensure reliable performance by your air conditioning and/or heating units.

Residential Service we offer includes Maintenance Agreements, Installation of new or replacement units, Service/Repair on your current units.

"Peak Performance" Residential Maintenance Agreements which include twice yearly (spring/fall) tune-ups ensure reliable performance.
Installation by experienced technician provides comfort and efficiency:
Service/Repair: Free Estimates on Replacements, 24 Hour Emergency Service, Service available on ALL Brands.

Commercial Service we offer includes our Commercial Maintenance Program (1-30 Tons), Installation of new and replacement units, Service/Repair on your current units.

Commercial Maintenance Program (1-30 Tons). We can prepare a custom maintenance schedule to fit your needs and coordinate site visits with your current in-house maintenance staff to provide a more comfortable environment and to ensure maximum efficiency and longevity of your equipment.
Installation by experienced technician provides comfort and efficiency:

Service/Repair: Free Estimates on Replacements, 24 Hour Emergency Service, Service available on ALL Brands.

Duct Leakage Testing:

Builders will soon need to get up to speed on duct testing, since recent code changes will require that all residential duct systems except those that are located entirely within a home’s thermal envelope will need to be tested for leakage.

If some ducts are outside of the thermal envelope, the 2009 IRC will require duct tightness to be verified by either a “rough-in test” or a “post-construction test.” Either test requires all register boots to be taped or otherwise sealed during the test.

The threshold for the rough-in test is total duct system leakage of 6 cfm per 100 square feet of conditioned floor area (when tested at 25 Pascals). If the air handler is not installed, the total leakage must be less than or equal to 4 cfm per 100 square feet of conditioned floor area.

Blower Door Testing:

Testing:Section N1102.4.1 of the 2012 International Residential Code (IRC) includes a requirement for blower-door testing with airtightness standards spelled out for the country’s various climate zones. New houses will need to meet or exceed these airtightness numbers to meet the current building code (see climate-zone map, below). Air Tight is Certified to do both Blower Door and Duct Depressurization test by BPI.